BOOK 2, CHAPTER 8: Directional Control Valves

07 Mar.,2024

 

Directional Control Valves

Directional control valves perform only three functions:

  • stop fluid flow
  • allow fluid flow, and
  • change direction of fluid flow.

These three functions usually operate in combination.

The simplest directional control valve is the 2-way valve. A 2-way valve stops flow or allows flow. A water faucet is a good example of a 2-way valve. A water faucet allows flow or stops flow by manual control.

A single-acting cylinder needs supply to and exhaust from its port to operate. This requires a 3-way valve. A 3-way valve allows fluid flow to an actuator in one position and exhausts the fluid from it in the other position. Some 3-way valves have a third position that blocks flow at all ports.

A double-acting actuator requires a 4-way valve. A 4-way valve pressurizes and exhausts two ports interdependently. A 3-position, 4-way valve stops an actuator or allows it to float. The 4-way function is a common type of directional control valve for both air and hydraulic circuits. A 3-position, 4-way valve is more common in hydraulic circuits.

The 5-way valve is found most frequently in air circuits. A 5-way valve performs the same function as a 4-way valve. The only difference is an extra tank or exhaust port. (Some suppliers call their 5-way valves, “5-ported 4-ways.") All spool valves are five ported, but hydraulic valves have internally connected exhaust ports going to a common outlet. Because oil must return to tank, it is convenient to connect the dual tank ports to a single return port. For air valves, atmosphere is the tank, so exhaust piping is usually unimportant. Using two exhaust ports makes the valve smaller and less expensive. As will be explained later, dual exhausts used for speed-control mufflers or as dual-pressure inlets make this configuration versatile.

Following are schematic symbols for commonly used directional control valves.

2-way directional control valves
A 2-way directional valve has two ports normally called inlet and outlet. When the inlet is blocked in the at-rest condition, as shown in Figure 8-1, it is referred to as "normally closed" (NC). The at-rest box or the normal condition is the one with the flow lines going to and from it.

The boxes or enclosures represent the valve’s positions. In Figure 8-1, the active box shows blocked ports, or a closed condition, while the upper box shows a flow path. When an operator shifts the valve, it is the same as sliding the upper box down to take the place of the lower box. In the shifted condition there is flow from inlet to outlet. Releasing the palm button in Figure 8-1 allows the valve spring to return to the normal stop flow condition. A 2-way valve makes a blow-off device or runs a fluid motor in one direction. By itself, a 2-way valve cannot cycle even a single acting cylinder.

If you have any questions on Types of Solenoid Valves, High Pressure Electro-Pneumatic Regulator. We will give the professional answers to your questions.