Lessons about Positive Displacement Flow Meters

29 Jul.,2024

 

Lessons about Positive Displacement Flow Meters

type of flow meter that provides high accuracy (±0.1% of actual flow rate in some cases) and good repeatability (as high as 0.05% of reading). These meters do not require a power supply for their operation and do not require straight upstream and downstream pipe runs for their installation. They are ideal for flow measurement of viscous fluids, such as oils, fuels, and solvents that are difficult for other types of flow meters to measure.

PD flow meters are most widely used as household water meters and millions of such units are produced annually. In industrial and petrochemical applications, positive displacement meters are commonly used for batch charging of both liquids and gases.

How Does a Positive Displacement Flow Meter Work?

All positive displacement flow meters operate by passing isolated, known volumes of a fluid through a series of gears or chambers within the meter. By counting the number of passed isolated volumes, a flow measurement is obtained. Each positive displacement design uses a different means of isolating and counting these volumes. The frequency of the resulting pulse train is a measure of flow rate, while the total number of pulses gives the size of the batch. While PD meters are operated by the kinetic energy of the flowing fluid, metering pumps determine the flow rate while also adding kinetic energy to the fluid.

PD meters are available in sizes from 1/4" to 12" and can operate with turndowns as high as 100:1, although ranges of 15:1 or lower are much more common. Slippage between the flow meter components is reduced and metering accuracy is therefore increased as the viscosity of the process fluid increases.

The process fluid must be clean and free from contaminants.Particles greater than 100 microns in size must be removed by filtering. PD meters operate with small clearances between their precision-machined parts; wear rapidly destroys their accuracy. For this reason, PD meters are generally not recommended for measuring slurries or abrasive/corrosive fluids. In clean fluid services, however, their precision and wide rangeability make them ideal for custody transfer and batch charging.

Although slippage through the PD meter decreases (that is, accuracy increases) as fluid viscosity increases, pressure drop through the meter also rises. Consequently, the maximum (and minimum) flow capacity of the flow meter is decreased as viscosity increases. The higher the viscosity, the less slippage and the lower the measurable flow rate becomes. As viscosity decreases, the low flow performance of the meter deteriorates. The maximum allowable pressure drop across the meter constrains the maximum operating flow in high viscosity services.

Please visit our website for more information on this topic.

Testing, Calibration, and Provers

All meters with moving parts require periodic testing, recalibration, and repair because wear increases the clearances. Recalibration can be done either in a laboratory or online using a prover.

Gas systems are recalibrated against a bell-jar prover &#; a calibrated cylindrical bell, liquid sealed in a tank. As the bell is lowered, it discharges a known volume of gas through the meter being tested. The volumetric accuracy of bell-jar provers is on the order of 0.1% by volume, and provers are available in discharge volumes of 2, 5, 10 ft3 and larger.

Liquid systems can be calibrated in the laboratory against either a calibrated secondary standard or a gravimetric flow loop. This approach can provide high accuracy (up to ±0.01% or rate) but requires removing the flow meter from service.

In many operations, especially in the petroleum industry, it is difficult or impossible to remove a flow meter from service for calibration. Therefore, field-mounted and in-line provers have been developed. This type of prover consists of a calibrated chamber equipped with a barrier piston (Figure 1). Two detectors are mounted a known distance (and therefore a known volume) apart. As the flow passes through the chamber, the displacer piston is moved downstream. Dividing the volume of the chamber by the time it takes for the displacer to move from one detector to the other gives the calibrated flow rate. This rate is then compared to the reading of the flow meter under test.


Figure 1: Field-Mounted, In-Line Flow Prover


Provers are repeatable on the order of 0.02%, and can operate at up to 3,000 psig and 165°F/75°C. Their operating flow range is from as ow as 0.001 gpm to as high as 20,000 gpm. Provers are available for bench-top use, for mounting in truck-beds, on trailers, or in-line.

PD Meter Accessories

PD meter accessories include strainers, filters, air/vapor release assemblies, pulsation dampeners, temperature compensations systems, and a variety of valves to permit dribble cut-off in batching systems. Mechanical registers can be equipped with mechanical or electronic ticket-printers for inventory control and point-of-use sales. Batching flow computers are readily available, as are analog and intelligent digital transmitters. Automatic meter reading (AMR) devices permit the remote retrieval of readings by utility personnel.

Benefits of Positive Displacement Flow Meters

There are many benefits that positive displacement flow meters offer &#; including:

Accuracy: One of the main benefits of using a PD flow meter is the high level of accuracy that they offer, the high precision of internal components means that clearances between sealing faces is kept to a minimum. The smaller these clearances are, relates to how high the accuracy will be. Only fluid that is able to bypass this seal does not get counted, this is known as &#;by-pass&#; or &#;slippage&#;.

Range and Repeatability: Another benefit is the flow meter&#;s ability to process a huge range of viscosities and it is not uncommon to experience higher levels of accuracy while processing high viscosity fluids, simply dues to the reduction of by-pass. When considering and comparing flow meter accuracy, it is important to be aware of both &#;linearity&#;&#;; i.e., the flow meter&#;s ability to accurately measure over the complete turndown ratio, and &#;repeatability&#;, the ability to remain accurate over a number of cycles. This is another area where PD flow meters excel, repeatability of 0.02% and 0.5% linearity are standard.

Reliability: If the correct flow meter has been selected for an application it can be expected to perform without error for many years. Frequently meters are sent in for servicing and recalibration that have been in the field for 10 sometimes 20 years continuous use. This reliability is largely due to the fact that this same proven technology has been in use for over 60 years, allowing the major advances to be focused within the fields of tribology and achieving the required precision at a reasonable cost.

Low Maintenance: The level of recommended maintenance is heavily influenced by the application. For example, if a flow meter is processing a fluid that displays lubricating properties i.e. oil, then routine maintenance can virtually be eliminated. If, however, the fluid has very poor lubricating properties then it is best to discuss the maintenance requirements with your distributor.

It is very uncommon that any maintenance to a PD flow meter would be more frequent than that of other equipment within the same system and can be scheduled to be carried out at the same time, minimalizing downtime.

Limitations of PD Flow Meters

While PD flow meters are very robust, there are limitations to their usage. Firstly, they should not be used for fluids that contain large particles, unless these can be filtered out prior to the fluid entering the measuring chamber. They are also not suitable for applications where large pockets of air are present within the fluid; however, air eliminators are available for these applications.

Another factor that requires consideration is the pressure drop caused by the PD flow meter; although these are minimal, they should also be allowed for in system calculations. As mentioned above when processing fluids with poor lubricating properties, it is recommended that advice is sought from your distributor; various material options are available for these applications.

Types of Positive Displacement Flow Meters

Operation of positive displacement (PD) flow meters consists of separating liquids into accurately measured increments and moving them on. Each segment is counted by a connecting register. Because every increment represents a discrete volume, positive displacement units are popular for automatic batching and accounting applications. Positive displacement flow meters are good candidates for measuring the flows of viscous liquids or for use where a simple mechanical meter system is needed.

Liquid Positive Displacement Flow Meters or Nutating Disk Meters

Nutating disc meters are the most common PD meters. They are used as residential water meters around the world. As water flows through the metering chamber, it causes a disc to wobble (nutate), turning a spindle, which rotates a magnet. This magnet is coupled to a mechanical register or a pulse transmitter. Because the flow meter entraps a fixed quantity of fluid each time the spindle is rotated, the rate of flow is proportional to the rotational velocity of the spindle (Figure 2-A).


Figure 2: Positive Displacement Flow Meter Designs


Because it must be nonmagnetic, the meter housing is usually made of bronze but can be made from plastic for corrosion resistance or cost savings. The wetted parts such as the disc and spindle are usually bronze, rubber, aluminum, neoprene, Buna-N, or a fluoroelastomer such as FKM. Nutating disc meters are designed for water service and the materials of which they are made must be checked for compatibility with other fluids. Meters with rubber discs give better accuracy than metal discs due to the better sealing they provide.

Nutating disc meters are available in 5/8-in to 2-in sizes. They are suited for 150-psig operating pressures with overpressure to a maximum of 300 psig. Cold water service units are temperature-limited to 120°F. Hot water units are available up to 250°F.

These meters must meet American Water Works Association (AWWA) standards for accuracy. The accuracy of these meters is required to be ±2% of actual flow rate. Higher viscosity can produce higher accuracy, while lower viscosity and wear over time will reduce accuracy. The AWWA requires that residential water meters be re-calibrated every 10 years. Because of the intermittent use patterns of residential users, this corresponds to recalibrating 5/8 x 3/4 in residential water meters after they have metered 5 million gallons. In industrial applications, however, these meters are likely to pass this threshold much sooner. The maximum continuous flow of a nutating disc meter is usually about 60-80% of the maximum flow in intermittent service.

Rotating vane meters (Figure 2-B) have spring-loaded vanes that entrap increments of liquid between the eccentrically mounted rotor and the casing. The rotation of the vanes moves the flow increment from inlet to outlet and discharge. Accuracy of ±0.1% of actual rate (AR) is normal, and larger size meters on higher viscosity services can achieve accuracy to within 0.05% of rate.

Rotating vane meters are regularly used in the petroleum industry and are capable of metering solids-laden crude oils at flow rates as high as 17,500 gpm. Pressure and temperature limits depend on the materials of construction and can be as high as 350°F and 1,000 psig. Viscosity limits are 1 to 25,000 centipoise.

In the rotary displacement meter, a fluted central rotor operates in constant relationship with two wiper rotors in a six-phase cycle. Its applications and features are similar to those of the rotary vane meter.

Oscillating Piston Flow Meters

Oscillating piston flow meters typically are used in viscous fluid services such as oil metering on engine test stands where turndown is not critical (Figure 3). These meters also can be used on residential water service and can pass limited quantities of dirt, such as pipe scale and fine (viz,-200 mesh or -74 micron) sand, but not large particle size or abrasive solids.


Figure 3: Piston Meter Designs


The measurement chamber is cylindrical with a partition plate separating its inlet port from its outlet. The piston is also cylindrical and is punctured by numerous openings to allow free flow on both sides of the piston and the post (Figure 2-A). The piston is guided by a control roller within the measuring chamber, and the motion of the piston is transferred to a follower magnet which is external to the flowstream. The follower magnet can be used to drive either a transmitter, a register, or both. The motion of the piston is oscillatory (not rotary) since it is constrained to move in one plane. The rate of flow is proportional to the rate of oscillation of the piston.

The internals of this flow meter can be removed without disconnection of the meter from the pipeline. Because of the close tolerances required to seal the piston and to reduce slippage, these meters require regular maintenance. Oscillating piston flow meters are available in 1/2-in to 3-in sizes and can generally be used between 100 and 150 psig. Some industrial versions are rated to 1,500 psig. They can meter flow rates from 1 gpm to 65 gpm in continuous service with intermittent excursions to 100 gpm. Meters are sized so that pressure drop is below 35 psid at maximum flow rate. Accuracy ranges from ±0.5 % AR for viscous fluids to ±2% AR for non-viscous applications. Upper limit on viscosity is 10,000 centipoise.

Reciprocating piston meters are probably the oldest PD meter designs. They are available with multiple pistons, double-acting pistons, or rotary pistons. As in a reciprocating piston engine, fluid is drawn into one piston chamber as it is discharged from the opposed piston in the meter. Typically, either a crankshaft or a horizontal slide is used to control the opening and closing of the proper orifices in the meter. These meters are usually smaller (available in sizes down to 1/10-in diameter) and are used for measuring very low flows of viscous liquids.

Oval Gear and Lobe Meters

The oval gear PD meter uses two fine-toothed gears, one mounted horizontally, the other vertically, with gears meshing at the tip of the vertical gear and the center of the horizontal gear (Figure 4-A). The two rotors rotate opposite to each other, creating an entrapment in the crescent-shaped gap between the housing and the gear. These meters can be very accurate if slippage between the housing and the gears is kept small. If the process fluid viscosity is greater than 10 centipoise and the flowrate is above 20% of rated capacity, accuracy of 0.1% AR can be obtained. At lower flows and at lower viscosity, slippage increases, and accuracy decreases to 0.5% AR or less.


Figure 4: Rotating Positive Displacement Meters


The lubricating characteristics of the process fluid also affect the turndown of an oval gear meter. With liquids that do not lubricate well, maximum rotor speed must be derated to limit wear. Another way to limit wear is to keep the pressure drop across the meter below 15 psid. Therefore, the pressure drop across the meter limits the allowable maximum flow in high viscosity service.

Rotating lobe and impeller type PD meters are variations of the oval gear flow meter that do not share its precise gearing. In the rotating lobe design, two impellers rotate in opposite directions within the ovoid housing (Figure 4-B). As they rotate, a fixed volume of liquid is entrapped and then transported toward the outlet. Because the lobe gears remain in a fixed relative position, it is only necessary to measure the rotational velocity of one of them. The impeller is either geared to a register or is magnetically coupled to a transmitter. Lobe meters can be furnished in 2-in to 24-in line sizes. Flow capacity is 8-10 gpm to 18,000 gpm in the larger sizes. They provide good repeatability (better than 0.015% AR) at high flows and can be used at high operating pressures (to 1,200 psig) and temperatures (to 400°F).

The lobe gear meter is available in a wide range of materials of construction, from thermoplastics to highly corrosion-resistant metals. Disadvantages of this design include a loss of accuracy at low flows. Also, the maximum flow through this meter is less than for the same size oscillatory piston or nutating disc meter.

In the rotating impeller meter, very coarse gears entrap the fluid and pass a fixed volume of fluid with each rotation (Figure 4-C). These meters are accurate to 0.5% of rate if the viscosity of the process fluid is both high and constant, or varies only within a narrow band. These meters can be made out of a variety of metals, including stainless steel, and corrosion-resistant plastics such as PVDF (Kynar). These meters are used to meter paints and, because they are available in 3A or sanitary designs, also milk, juices, and chocolate.

In these units, the passage of magnets embedded in the lobes of the rotating impellers is sensed by proximity switches (usually Hall-effect detectors) mounted external to the flow chamber. The sensor transmits a pulse train to a counter or flow controller. These meters are available in 1/10-in to 6-in sizes and can handle pressures to 3,000 psig and temperatures to 400°F.

Helix Meters

The helix meter is a positive displacement device that uses two radially pitched helical gears to continuously entrap the process fluid as it flows. The flow forces the helical gears to rotate in the plane of the pipeline. Optical or magnetic sensors are used to encode a pulse train proportional to the rotational speed of the helical gears. The forces required to make the helices rotate are relatively small and therefore, in comparison to other PD meters, the pressure drop is relatively low. The best attainable accuracy is about ±0.2% or rate.


Figure 5: Effect of Viscosity on Low-Flow Accuracy


As shown in Figure 5, measurement error rises as either the operating flowrate or the viscosity of the process fluid drops. Helical gear meters can measure the flow of highly viscous fluids (from 3 to 300,000 cP), making them ideal for extremely thick fluids such as glues and very viscous polymers. Because at maximum flow the pressure drop through the meter should not exceed 30 psid, the maximum rated flow through the meter is reduced as the fluid viscosity increases. If the process fluid has good lubricating characteristics, the meter turndown can be as high as 100:1, but lower (10:1) turndowns are more typical.

Metering Pumps

Metering pumps are PD meters that also impart kinetic energy to the process fluid. There are three basic designs: peristaltic, piston, and diaphragm.

Peristaltic pumps operate by having fingers or a cam systematically squeeze a plastic tubing against the housing, which also serves to position the tubing. This type of metering pump is used in laboratories, in a variety of medical applications, in the majority of environmental sampling systems, and also in dispensing hypochlorite solutions. The tubing can be silicone-rubber or, if a more corrosion-resistant material is desired, PTFE tubing.

Piston pumps deliver a fixed volume of liquid with each "out" stroke and a fixed volume enters the chamber on each "in" stroke (Figure 6-A). Check valves keep the fluid flow from reversing. As with all positive displacement pumps, piston pumps generate a pulsating flow. To minimize the pulsation, multiple pistons or pulsation-dampening reservoirs are installed. Because of the close tolerances of the piston and cylinder sleeve, a flushing mechanism must be provided in abrasive applications. Piston pumps are sized on the basis of the displacement of the piston and the required flow rate and discharge pressure. Check valves (or, on critical applications, double check valves) are selected to protect against backflow.


Figure 6: Metering Pump Designs


Diaphragm pumps are the most common industrial PD pumps (Figure 6-B). A typical configuration consists of a single diaphragm, a chamber, and suction and discharge check valves to prevent backflow. The piston can either be directly coupled to the diaphragm or can force a hydraulic oil to drive the diaphragm. Maximum output pressure is about 125 psig. Variations include bellows-type diaphragms, hydraulically actuated double diaphragms, and air-operated, reciprocating double-diaphragms.

Gas Positive Displacement Flow Meters

PD gas meters operate by counting the number of entrapped volumes of gas passed, similar to the way PD meters operate on liquids. The primary difference is that gases are compressible.

Diaphragm gas meters most often are used to measure the flow of natural gas, especially in metering consumption by households. The meter is constructed from aluminum castings with cloth-backed rubber diaphragms. The meter consists of four chambers: the two diaphragm chambers on the inlet and outlet sides and the inlet and outlet chambers of the meter body. The passage of gas through the meter creates a differential pressure between the two diaphragm chambers by compressing the one on the inlet side and expanding the one on the outlet side. This action alternately empties and fills the four chambers. The slide valves at the top of the meter alternate the roles of the chambers and synchronize the action of the diaphragms, as well as operating the crank mechanism for the meter register.

Diaphragm meters generally are calibrated for natural gas, which has a specific gravity of 0.6 (relative to air). Therefore, it is necessary to re-calibrate the flow rating of the meter when it is used to meter other gases. The calibration for the new flow rating (QN) is obtained by multiplying the meter's flow rating for natural gas (QC) by the square root of the ratio of the specific gravities of natural gas (0.6) and the new gas (SGN):

Qn=Qc(0.6/SGn)1.5

Diaphragm meters are usually rated in units of cubic feet per hour and sized for a pressure drop of 0.5-2 in H2O. Accuracy is roughly ±1% of reading over a 200:1 range. They maintain their accuracy for long periods of time, which makes them good choices for retail revenue metering applications. Unless the gas is unusually dirty (producer gas, or recycled methane from composting or digesting, for example), the diaphragm meter will operate with little or no maintenance indefinitely.

Lobe gear meters (or lobed impeller meters, as they are also known), also are used for gas service. Accuracy in gas service is ±1% of rate over a 10:1 turndown, and typical pressure drop is 0.1 psid. Because of the close tolerances, upstream filtration is required for dirty lines.

Rotating vane meters measure the flow of gas in the same ranges as do lobe gear meters (up to 100,000 ft3/hr) but can be used over a wider 25:1 turndown. They also incur a lower pressure drop of 0.05 in H2O for similar accuracy, and, because the clearances are somewhat more forgiving, upstream filtration is not as critical.

High-Precision Positive Displacement Systems

High-precision gas meters are usually a hybrid combining a standard positive displacement meter and a motor drive that eliminates the pressure drop across the meter. Equalizing the inlet and outlet pressures eliminates slip flows, leakage, and blow-by. In high-precision gas flow meter installations, high-sensitivity leaves are used to detect the pressure differential, and displacement transducers are used to measure the deflection of the leaves (Figure 7-A). Designed to operate at ambient temperatures and at up to 30 psig pressures, this meter is claimed to provide accuracy to within 0.25% of reading over a 50:1 range and 0.5% over a 100:1 range. Flow capacity ranges from 0.3-1,500 scfm.


Figure 7: High-Pressure PD Meters Equalize Inlet and Outlet Pressures


For liquid service, a servomotor-driven oval-gear meter equalizes the pressure across the meter. This increases accuracy at low flows and under varying viscosity conditions (Figure 7- B). This flow meter uses a very sensitive piston to detect the meter differential and drives a variable speed servomotor to keep it near zero. This design is claimed to provide 0.25% of rate accuracy over a 50:1 range at operating pressures of up to 150 psig. High precision flow meters are used on engine test stands for fuel flow measurement (gasoline, diesel, alcohol, etc.). Flow ranges from 0.04-40 gph are typical. Vapor separators are usually included, to prevent vapor lock.

Related articles to:

Lessons about Positive Displacement Flow Meters

Product Info

What Is An Anemometer And What Does It Measure? Introduction to Air Velocity Measurement

Technical Learning

Doppler Meters Vs Transit Time Ultrasonic Flow Meters

Flow Meter Types - Principle - MaxiFlo

FLOWMETER TYPES AND THEIR PRINCIPLES

INTRODUCTION

Measuring the flow of liquids is a critical need in many industrial plants. In some operations, the ability to conduct accurate flow measurements is so important that it can make the difference between making a profit or taking a loss. In other cases, inaccurate flow measurements or failure to take measurements can cause serious (or even disastrous) results.

With most liquid flow measurement instruments, the flow rate is determined inferentially by measuring the liquid's velocity or the change in kinetic energy. Velocity depends on the pressure differential that is forcing the liquid through a pipe or conduit. Because the pipe's cross-sectional area is known and remains constant, the average velocity is an indication of the flow rate. The basic relationship for determining the liquid's flow rate in such cases is:

Q = V x A

where

Q = liquid flow through the pipe

V = average velocity of the flow

A = cross-sectional area of the pipe


Other factors that affect liquid flow rate include the liquid's viscosity and density, and the friction of the liquid in contact with the pipe.

Direct measurements of liquid flows can be made with positive-displacement flowmeters. These units divide the liquid into specific increments and move it on. The total flow is an accumulation of the measured increments, which can be counted by mechanical or electronic techniques.

Reynolds Numbers

The performance of flowmeters is also influenced by a dimensionless unit called the Reynolds Number. It is defined as the ratio of the liquid's inertial forces to its drag forces.


Figure 1: Laminar and turbulent flow are two types normally encountered in liquid flow Measurement operations. Most applications involve turbulent flow, with R values above . Viscous liquids usually exhibit laminar flow, with R values below . The transition zone between the two levels may be either laminar or turbulent.

The equation is:

R = x Q x Gt
D x h

where:

R = Reynolds number

Q = liquid's flow rate, gpm

Gt = liquid's specific gravity

D = inside pipe diameter, in.

h = liquid's viscosity, cp

 

tnma are exported all over the world and different industries with quality first. Our belief is to provide our customers with more and better high value-added products. Let's create a better future together.

The flow rate and the specific gravity are inertia forces, and the pipe diameter and viscosity are drag forces. The pipe diameter and the specific gravity remain constant for most liquid applications. At very low velocities or high viscosities, R is low, and the liquid flows in smooth layers with the highest velocity at the center of the pipe and low velocities at the pipe wall where the viscous forces restrain it. This type of flow is called laminar flow. R values are below approximately . A characteristic of laminar flow is the parabolic shape of its velocity profile, Fig. 1.

However, most applications involve turbulent flow, with R values above . Turbulent flow occurs at high velocities or low viscosities. The flow breaks up into turbulent eddies that flow through the pipe with the same average velocity. Fluid velocity is less significant, and the velocity profile is much more uniform in shape. A transition zone exists between turbulent and laminar flows. Depending on the piping configuration and other installation conditions, the flow may be either turbulent or laminar in this zone.

FLOWMETER TYPES

Numerous types of flowmeters are available for closed-piping systems. In general, the equipment can be classified as differential pressure, positive displacement, velocity, and mass meters. Differential pressure devices (also known as head meters) include orifices, venturi tubes, flow tubes, flow nozzles, pitot tubes, elbow-tap meters, target meters, and variable-area meters, Fig. 2.

Positive displacement meters include piston, oval-gear, nutating-disk, and rotary-vane types. Velocity meters consist of turbine, vortex shedding, electromagnetic, and sonic designs. Mass meters include Coriolis and thermal types. The measurement of liquid flows in open channels generally involves weirs and flumes.

Space limitations prevent a detailed discussion of all the liquid flowmeters available today. However, summary characteristics of common devices are shown in Table 1. (Click here to see Selection Guide) Brief descriptions follow.

Differential Pressure Meters

The use of differential pressure as an inferred measurement of a liquid's rate of flow is well known. Differential pressure flowmeters are, by far, the most common units in use today. Estimates are that over 50 percent of all liquid flow measurement applications use this type of unit.

The basic operating principle of differential pressure flowmeters is based on the premise that the pressure drop across the meter is proportional to the square of the flow rate. The flow rate is obtained by measuring the pressure differential and extracting the square root.

Differential pressure flowmeters, like most flowmeters, have a primary and secondary element. The primary element causes a change in kinetic energy, which creates the differential pressure in the pipe. The unit must be properly matched to the pipe size, flow conditions, and the liquid's properties. And, the measurement accuracy of the element must be good over a reasonable range. The secondary element measures the differential pressure and provides the signal or read-out that is converted to the actual flow value.

Orifices are the most popular liquid flowmeters in use today. An orifice is simply a flat piece of metal with a specific-sized hole bored in it. Most orifices are of the concentric type, but eccentric, conical (quadrant), and segmental designs are also available.

In practice, the orifice plate is installed in the pipe between two flanges. Acting as the primary device, the orifice constricts the flow of liquid to produce a differential pressure across the plate. Pressure taps on either side of the plate are used to detect the difference. Major advantages of orifices are that they have no moving parts and their cost does not increase significantly with pipe size.

Conical and quadrant orifices are relatively new. The units were developed primarily to measure liquids with low Reynolds numbers. Essentially constant flow coefficients can be maintained at R values below . Conical orifice plates have an upstream bevel, the depth and angle of which must be calculated and machined for each application.

The segmental wedge is a variation of the segmental orifice. It is a restriction orifice primarily designed to measure the flow of liquids containing solids. The unit has the ability to measure flows at low Reynolds numbers and still maintain the desired square-root relationship. Its design is simple, and there is only one critical dimension the wedge gap. Pressure drop through the unit is only about half that of conventional orifices.

Integral wedge assemblies combine the wedge element and pressure taps into a one-piece pipe coupling bolted to a conventional pressure transmitter. No special piping or fittings are needed to install the device in a pipeline.

Metering accuracy of all orifice flowmeters depends on the installation conditions, the orifice area ratio, and the physical properties of the liquid being measured. (Back to Meter Types Table)

Venturi tubes have the advantage of being able to handle large flow volumes at low pressure drops. A venturi tube is essentially a section of pipe with a tapered entrance and a straight throat. As liquid passes through the throat, its velocity increases, causing a pressure differential between the inlet and outlet regions.

The flowmeters have no moving parts. They can be installed in large diameter pipes using flanged, welded or threaded-end fittings. Four or more pressure taps are usually installed with the unit to average the measured pressure. Venturi tubes can be used with most liquids, including those having a high solids content. (Back to Meter Types Table)

Flow tubes are somewhat similar to venturi tubes except that they do not have the entrance cone. They have a tapered throat, but the exit is elongated and smooth. The distance between the front face and the tip is approximately one-half the pipe diameter. Pressure taps are located about one-half pipe diameter downstream and one pipe diameter upstream. (Back to Meter Types Table)

Flow Nozzles, at high velocities, can handle approximately 60 percent greater liquid flow than orifice plates having the same pressure drop. Liquids with suspended solids can also be metered. However, use of the units is not recommended for highly viscous liquids or those containing large amounts of sticky solids. (Back to Meter Types Table)

Pitot tubes sense two pressures simultaneously, impact and static. The impact unit consists of a tube with one end bent at right angles toward the flow direction. The static tube's end is closed, but a small slot is located in the side of the unit. The tubes can be mounted separately in a pipe or combined in a single casing.

Pitot tubes are generally installed by welding a coupling on a pipe and inserting the probe through the coupling. Use of most pitot tubes is limited to single point measurements. The units are susceptible to plugging by foreign material in the liquid. Advantages of pitot tubes are low cost, absence of moving parts, easy installation, and minimum pressure drop.(Back to Meter Types Table)

Elbow tap meters operate on the principle that when liquid travels in a circular path, centrifugal force is exerted along the outer edges. Thus, when liquid flows through a pipe elbow, the force on the elbow's interior surface is proportional to the density of the liquid times the square of its velocity. In addition, the force is inversely proportional to the elbow's radius.

Any 90 deg. pipe elbow can serve as a liquid flowmeter. All that is required is the placement of two small holes in the elbow's midpoint (45 deg. point) for piezometer taps. Pressure-sensing lines can be attached to the taps by using any convenient method.  The difference in pressure on the outside and inside walls, caused by centrifugal force, can be measured with a differential pressure transducer. Figure 2 shows a typical installation.

Pressure measurements are obtained by placing taps at 45- degree angles on opposite sides of the elbow. The size of each of the two taps should not exceed one-eighth of the pipe diameter. Flow is calculated according to the following formula:

 W = 244 [SQ.ROOT SIGN] rhD3p

 where W = flow in pounds per hour

r = elbow radius (inches)

D = elbow diameter (inches)

h = differential pressure (inches H20)

p = density in lbs/ft3

(Back to Meter Types Table)

Target meters sense and measure forces caused by liquid impacting on a target or drag-disk suspended in the liquid stream. A direct indication of the liquid flow rate is achieved by measuring the force exerted on the target. In its simplest form, the meter consists only of a hinged, swinging plate that moves outward, along with the liquid stream. In such cases, the device serves as a flow indicator.

A more sophisticated version uses a precision, low-level force transducer sensing element. The force of the target caused by the liquid flow is sensed by a strain gage. The output signal from the gage is indicative of the flow rate. Target meters are useful for measuring flows of dirty or corrosive liquids.(Back to Meter Types Table)

Variable-area meters, often called rotameters, consist essentially of a tapered tube and a float, Fig. 3. Although classified as differential pressure units, they are, in reality, constant differential pressure devices. Flanged-end fittings provide an easy means for installing them in pipes. When there is no liquid flow, the float rests freely at the bottom of the tube. As liquid enters the bottom of the tube, the float begins to rise. The float is selected so as to have a density higher than that of the fluid and the position of the float varies directly with the flow rate. Its exact position is at the point where the differential pressure between the upper and lower surfaces balance the weight of the float.

Because the flow rate can be read directly on a scale mounted next to the tube, no secondary flow-reading devices are necessary. However, if desired, automatic sensing devices can be used to sense the float's level and transmit a flow signal. Rotameter tubes are manufactured from glass, metal, or plastic. Tube diameters vary from 1/4 to greater than 6 in. (Back to Meter Types Table)

 

Positive-Displacement Meters

Operation of these units consists of separating liquids into accurately measured increments and moving them on. Each segment is counted by a connecting register. Because every increment represents a discrete volume, positive-displacement units are popular for automatic batching and accounting applications. Positive-displacement meters are good candidates for measuring the flows of viscous liquids or for use where a simple mechanical meter system is needed.

Reciprocating piston meters are of the single and multiple-piston types. The specific choice depends on the range of flow rates required in the particular application. Piston meters can be used to handle a wide variety of liquids. A magnetically driven, oscillating piston meter is shown in Fig. 4. Liquid never comes in contact with gears or other parts that might clog or corrode. (Back to Meter Types Table)

Oval-gear meters have two rotating, oval-shaped gears with synchronized, close fitting teeth. A fixed quantity of liquid passes through the meter for each revolution. Shaft rotation can be monitored to obtain specific flow rates. (Back to Meter Types Table)

Nutating-disk meters have a moveable disk mounted on a concentric sphere located in a spherical side-walled chamber. The pressure of the liquid passing through the measuring chamber causes the disk to rock in a circulating path without rotating about its own axis. It is the only moving part in the measuring chamber. (Back to Meter Types Table)

A pin extending perpendicularly from the disk is connected to a mechanical counter that monitors the disk's rocking motions. Each cycle is proportional to a specific quantity of flow. As is true with all positive-displacement meters, viscosity variations below a given threshold will affect measuring accuracies. Many sizes and capacities are available. The units can be made from a wide selection of construction materials.

Rotary-vane meters are available in several designs, but they all operate on the same principle. The basic unit consists of an equally divided, rotating impeller (containing two or more compartments) mounted inside the meter's housing. The impeller is in continuous contact with the casing. A fixed volume of liquid is swept to the meter's outlet from each compartment as the impeller rotates. The revolutions of the impeller are counted and registered in volumetric units.

Helix flowmeters consist of two radically pitched helical rotors geared together, with a small clearance between the rotors and the casing. The two rotors displace liquid axially from one end of the chamber to the other. (Back to Meter Types Table)

Velocity Meters

These instruments operate linearly with respect to the volume flow rate. Because there is no square-root relationship (as with differential pressure devices), their rangeability is greater. Velocity meters have minimum sensitivity to viscosity changes when used at Reynolds numbers above 10,000. Most velocity-type meter housings are equipped with flanges or fittings to permit them to be connected directly into pipelines.

Turbine meters have found widespread use for accurate liquid measurement applications. The unit consists of a multiple-bladed rotor mounted with a pipe, perpendicular to the liquid flow. The rotor spins as the liquid passes through the blades. The rotational speed is a direct function of flow rate and can be sensed by magnetic pick-up, photoelectric cell, or gears. Electrical pulses can be counted and totalized, Fig. 5.

The number of electrical pulses counted for a given period of time is directly proportional to flow volume. A tachometer can be added to measure the turbine's rotational speed and to determine the liquid flow rate. Turbine meters, when properly specified and installed, have good accuracy, particularly with low-viscosity liquids.

A major concern with turbine meters is bearing wear. A "bearingless" design has been developed to avoid this problem. Liquid entering the meter travels through the spiraling vanes of a stator that imparts rotation to the liquid stream. The stream acts on a sphere, causing it to orbit in the space between the first stator and a similarly spiraled second stator. The orbiting movement of the sphere is detected electronically. The frequency of the resulting pulse output is proportional to flow rate. (Back to Meter Types Table)

Vortex meters make use of a natural phenomenon that occurs when a liquid flows around a bluff object. Eddies or vortices are shed alternately downstream of the object. The frequency of the vortex shedding is directly proportional to the velocity of the liquid flowing through the meter, Fig. 6.

The three major components of the flowmeter are a bluff body strut-mounted across the flowmeter bore, a sensor to detect the presence of the vortex and to generate an electrical impulse, and a signal amplification and conditioning transmitter whose output is proportional to the flow rate, Fig. 7. The meter is equally suitable for flow rate or flow totalization measurements. Use for slurries or high viscosity liquids is not recommended.

(Back to Meter Types Table)

Swirl Meter  The principle of operation of a swirl flowmeter is as follows. The meter body has a set of blades welded at the inlet, called the swirler. These blades impart a tangential velocity (or swirl) to liquids, gases or vapors. The fluid is then accelerated by a reduction in the meter body bore. A piezoelectric sensor is located in the center of the meter at the point of maximum fluid velocity. Flow is then decelerated as it approaches the meter outlet by an increase in meter body bore. A deswirler is welded to the meter body near the outlet. This deswirler eliminates the tangential velocity imparted to the fluid at the inlet so that other instrumentation downstream of the meter will not be affected by its operation.

            A swirl flowmeter consists of the flowmeter body and an electronics housing (the electronics can be remote mounted for safety or convenience). Swirlmeters are only available with flanged meter bodies. A wafer option is not available, as there is for vortex meters. Swirlmeters use the same sensors and electronics as vortex meters, only the meter bodies differ in design. Swirlmeters are most cost effective with stainless steel construction, although Hastelloy is also offered. Swirlmeters are available in sizes from ?to 16 inches, and have options for ANSI 150, 300 or 600 mating flanges.

            The primary rotation caused by the swirler has at its core a low-pressure zone. The low-pressure zone is thrown into a secondary rotation proportional to flow rate. This rotating low-pressure zone can be likened to a helical coil. At low flow rates, the low-pressure swirls are farther apart (the helical coil is stretched out). At higher flows, the low-pressure swirls are closer together (the coil is compressed). Areas of slightly higher pressure separate the low-pressure swirls. The sensor will deflect (to the left and then to the right) as a pressure swirl passes from one side to other. The alternating deflection of the sensor produces a sine wave voltage output, similar to the output shown in the vortex section. The frequency of this output voltage is the same frequency as the rotating low-pressure zones, and is therefore proportional to the volumetric flow rate.

            The swirl flowmeter factor does not exhibit the same deviation at high Reynolds numbers as does the vortex meter factor. This has been verified by testing on water and air at independent facilities. For this reason, a swirlmeter factor determined by water calibration is universally valid for all fluids. The swirlmeter, based on the water calibration, has a published accuracy of 0.5 percent of rate for liquids, gases or steam.

            As with the vortex meter, swirlmeter rangeability is fixed by the size of the meter and the fluid properties. The sensor requires a minimum strength pressure pulse to be able to distinguish the flow signal from hydraulic noise. While turbulent flow is required at all times, the swirlmeter does not have the same limitation on Reynolds number, as does the vortex meter and can generally measure lower flows. On the other hand, the swirlmeter body presents more of an obstruction to flow than does the vortex meter, and creates higher permanent head losses under similar conditions. For this reason, the swirlmeter does not measure flow rates as high as the vortex meter. The swirlmeter, like the vortex meter, averages 10:1 turndowns or higher on liquids, and 20:1 or higher on gases and vapors. However, the flow range of a 2-inch swirlmeter will be different than the flow range of a 2-inch vortex meter under the same operating conditions. Just as for a vortex meter, you select the swirlmeter size to achieve a desired flow range given the process conditions, and never to match the process piping. Swirlmeters have to be downsized (using a 2-inch meter for 3-inch process piping) less frequently than vortex meters. Free computer software is available from manufacturers that make sizing swirl flowmeters quick and easy.

Swirl Flowmeter Application Information

Swirlmeters cost about 50 percent more than the same size vortex meter because of the added complexity and welding requirements. The rule of thumb is to use the vortex meter whenever possible for cost, and use the swirlmeter for:

  •  Tight piping situations.

  •  More viscous liquids (8 cp < μ < 30 cp).

  •  Lower flow measurement capability.

  •  Higher accuracy on gases and steam.

  •  When downsizing to install a vortex meter is not feasible (head loss).

  • These meters are compatible with low viscosity (< 30 cp) liquids, gases and steam.

            Swirlmeters are less affected by as many real world parameters as orifice plates and turbine meters, and are less sensitive to piping effects than vortex meters. Swirlmeters require just 3 diameters of straight pipe upstream (regardless of bends, valves, etc.), and either 1 or 3 diameters of straight pipe downstream (the latter only required when a control valve is downstream of the meter).

            Like vortex meters, they measure velocity and infer actual volumetric flow rate from the known geometry of the meter body. Swirlmeters are generally used with flow computers to measure flow in standard volumetric or mass units (along with external pressure and/or temperature measurements). The flow computer is not necessary if the fluid density is constant. A pressure tap is provided on the meter body for making the pressure measurement (using an external sensor). The temperature element should be located downstream of the meter if needed.

            The swirlmeter does not measure to true zero flow. There is a flow cut-off point below which the meter output is automatically clamped at zero (4 mA for analog output). For most applications, this limitation does not pose a problem, as the swirlmeter has good low flow capability. However, this can be a draw back for applications where flows during start-up or shutdown operations, or other upset conditions, can be greatly different than under normal operating conditions. Users may need an indication of flow under such upsets, even if they do not need to measure flow accurately, making use of the swirlmeter questionable.

            Swirlmeters may also be questionable for some batching applications, especially if the pipe does not remain full between batches. The meter will not register flow as the fluid accelerates from zero to the cut-off value, and as the fluid decelerates back to zero at the end of the batch. Swirlmeters are unidirectional and will not measure or subtract any backflow from the batch total. This may create significant measurement errors, depending on the system dynamics, and the size of the batch.

            There may be a potential problem installing swirlmeters on existing processes where the flow range to be measured is completely unknown. Many times, the instrument engineer makes an educated guess on flow range. A swirlmeter sized for the wrong flow range, or wrong process conditions, may need to be replaced by a different size meter entirely. Other devices, like magnetic flowmeters, orifice plates and turbine meters, are more forgiving, and can be easily adapted to fit the actual process conditions after installation.

            Measuring gas flows when the process pressure is low (low-density gases) is less of a problem for swirlmeters than for vortex meters. Low-density gases can be measured with a swirlmeter, however rangeability may be less than the 20:1 mentioned previously, and extreme care must be taken in selecting the correct size meter.

            Measurement of multi-phase flow has lower accuracy than for single-phase fluids. The meter will measure the flow of all phases present and report it as all liquid or gas (depending on how the meter is configured). The secondary phase should be removed, if feasible, before the meter for the highest accuracy. Any secondary phase should be homogeneously dispersed and should not have any potential for sticking to or coating the meter. There is no evidence to suggest that a swirlmeter has any advantage over a vortex meter in regards to measuring multi-phase flow.

            Pressure drop must also be considered when selecting a swirlmeter. Flashing and cavitation have an adverse affect on meter accuracy, and can damage the meter itself. It was previously stated that a swirlmeter produces higher head loss than a vortex meter under the same conditions, up to five times higher. However, this is not a fair comparison. In real practice, the head loss for the swirlmeter is about the same as for the vortex meter, because you generally use a larger size swirlmeter than vortex meter to handle the same application.

            Fluids that tend to form coatings are bad applications for swirlmeters.

Installation Recommendations

One of the main advantages of the swirlmeter is its insensitivity to piping effects. It is an excellent meter for tight piping situations.

            Swirlmeters can be installed vertically, horizontally or at any angle. Allow liquids to flow against gravity to keep the pipe full. When the liquid is moving with gravity, elevate the downstream piping above the meter installation level to maintain a full pipe. Install the meter to avoid standing liquid when the pipe is empty. Also plan for the installation so as to avoid formation of gas bubbles in liquid flow. Check valves may be used when installing a vortex meter to keep it full of liquid when there is no active flow in the process.

            Mating flanges on the process piping must be of the same nominal size as on the flowmeter. Flanges with a smooth bore, similar to weld neck flanges, are preferred. Do not use reducing flanges. Most performance specifications are based upon using Schedule 40 or Schedule 80 mating pipe. The mating pipe should be of good quality, and have an internal surface free from mill scale, pits, holes, reaming scores, bumps, etc., for a distance of 4 diameters upstream and 2 diameters downstream of the meter. The bores of the adjacent piping, meter and gaskets should be aligned to prevent steps.

            Control valves should be placed no closer than 3 pipe diameters upstream or 3 pipe diameters downstream of the meter.

            The sensor used in the swirlmeter can be replaced in the field, but does require process shutdown. The meter should be installed with blocking valves, or in a bypass line, if process shutdown for maintenance poses a problem.

            Excessive pipe vibration or process noise can affect measurement accuracy. Mechanical pipe vibration can be eliminated by placing proper piping supports on either side of the meter, or by rotating the meter in the process piping so that the sensor is located in a plane different than the vibration. Process noise (from chattering valves, steam traps, pumps, etc.) is hydraulically connected to the meter by the fluid. The swirlmeter uses the same electronics with digital signal processing, as the vortex meter, to eliminate the adverse effects of vibration and noise, without sacrificing rangeability.

Conada Effect Flowmeter & Momentum Exchange Flowmeter.  While vortex shedding flowmeters are the most recognized types of oscillating flow measurement devices, less well known are meters based on the Coanda Effect, and the phenomenon known as momentum exchange.

         The Coanda Effect is named after aerodynamicist Henri-Marie Coanda, who discovered that a free jet emerging from a nozzle or conduit will follow a nearby surface and attach to it. Fluid flowing through the meter body bends toward and attaches to a sidewall. A portion of the flow is diverted through a feedback passage, however, and pushes the stream toward a sidewall on the opposite side of the meter body, which also has a feedback passage through which a portion of the flow is diverted. The fluid from this feedback passage pushes the stream back toward the sidewall to which it was initially attached, and the self-initiating, self-sustaining process is repeated. A sensor, located in one of the two feedback passages, detects the presence and absence of flow. The frequency of the pulse signals is linear with volumetric flow rate.

         The momentum exchange flowmeter is similar to the Coanda model, but relies on a different mechanism to create oscillations. Unlike the Coanda meter, the momentum exchange meter does not have sidewalls. The shape of the meter body creates a main flow that passes through the nozzle and towards one side of the meter body or the other. This creates a flow pulse in a feedback passage, exerting a force on the main jet and deflecting it so it exerts a force on the fluid in the opposite passage. The pattern repeats continuously, creating a self-sustaining oscillation. Like the Coanda meter, it has a sensor in one of the feedback passages that detects the pulsing of fluids.

       While most oscillating flowmeters -- including the Coanda fluidic flowmeter -- require turbulent flows to function, the momentum exchange meter does not, enabling its use with high-viscosity fluids.

           Like other types of oscillating flowmeters, benefits include minimum maintenance, high stability and relatively inexpensive purchase cost. However, they are limited to use on pipes four inches in diameter or less. Use of larger pipes would create too few pulses per gallon for accurate measurement.(Back to Meter Types Table)

 

Electromagnetic meters can handle most liquids and slurries, providing that the material being metered is electrically conductive. Major components are the flow tube (primary element), Fig. 8. The flow tube mounts directly in the pipe. Pressure drop across the meter is the same as it is through an equivalent length of pipe because there are no moving parts or obstructions to the flow. The voltmeter can be attached directly to the flow tube or can be mounted remotely and connected to it by a shielded cable.

Electromagnetic flowmeters operate on Faraday's law of electromagnetic induction that states that a voltage will be induced when a conductor moves through a magnetic field. The liquid serves as the conductor; the magnetic field is created by energized coils outside the flow tube, Fig. 9. The amount of voltage produced is directly proportional to the flow rate. Two electrodes mounted in the pipe wall detect the voltage, which is measured by the secondary element.

Electromagnetic flowmeters have major advantages: They can measure difficult and corrosive liquids and slurries; and they can measure forward as well as reverse flow with equal accuracy. Disadvantages of earlier designs were high power consumption, and the need to obtain a full pipe and no flow to initially set the meter to zero. Recent improvements have eliminated these problems. Pulse-type excitation techniques have reduced power consumption, because excitation occurs only half the time in the unit. Zero settings are no longer required.

(Back to Meter Types Table)

Ultrasonic flowmeters can be divided into Doppler meters and time-of-travel (or transit) meters.

Doppler meters measure the frequency shifts caused by liquid flow. Two transducers(one to transmit and the other to receive signal) are mounted in a case attached to one side of the pipe. A signal of known frequency is sent into the liquid to be measured. Solids, bubbles, or any discontinuity in the liquid, cause the pulse to be reflected to the receiver element, Fig. 10. Because the liquid causing the reflection is moving, the frequency of the returned pulse is shifted. The frequency shift is proportional to the liquid's velocity.

A portable Doppler meter capable of being operated on AC power or from a rechargeable power pack has recently been developed. The sensing heads are simply clamped to the outside of the pipe, and the instrument is ready to be used. Total weight, including the case, is 22 lb. A set of 4 to 20 millampere output terminals permits the unit to be connected to a strip chart recorder or other remote device.

Because solids particles or entrained gases are required for measurement, Doppler meters are not appropriate for clean liquids. In general, Doppler flowmeters are less accurate than TOF flowmeters, however, they are less expensive.
(Back to Meter Types Table)

Time-of-travel(Transit-Time) meters have transducers mounted on each side of the pipe. The configuration is such that the sound waves traveling between the devices are at a 45 deg. angle to the direction of liquid flow. The speed of the signal traveling between the transducers increases or decreases with the direction of transmission and the velocity of the liquid being measured. A time-differential relationship proportional to the flow can be obtained by transmitting the signal alternately in both directions.

A limitation of time-of-travel meters is that the liquids being measured must be relatively free of entrained gas or solids to minimize signal scattering and absorption. (Back to Meter Types Table)

 

Mass Flowmeters

The continuing need for more accurate flow measurements in mass-related processes (chemical reactions, heat transfer, etc.) has resulted in the development of mass flowmeters. Various designs are available, but the one most commonly used for liquid flow applications is the Coriolis meter. Its operation is based on the natural phenomenon called the Coriolis force, hence the name.

Coriolis meters are true mass meters that measure the mass rate of flow directly as opposed to volumetric flow. Because mass does not change, the meter is linear without having to be adjusted for variations in liquid properties. It also eliminates the need to compensate for changing temperature and pressure conditions. The meter is especially useful for measuring liquids whose viscosity varies with velocity at given temperatures and pressures.

Coriolis meters are also available in various designs. A popular unit consists of a U-shaped flow tube enclosed in a sensor housing connected to an electronics unit. The sensing unit can be installed directly into any process. The electronics unit can be located up to 500 feet from the sensor.

Inside the sensor housing, the U-shaped flow tube is vibrated at its natural frequency by a magnetic device located at the bend of the tube. The vibration is similar to that of a tuning fork, covering less than 0.1 in. and completing a full cycle about 80 times/sec. As the liquid flows through the tube, it is forced to take on the vertical movement of the tube, Fig. 11. When the tube is moving upward during half of its cycle, the liquid flowing into the meter resists being forced up by pushing down on the tube.

Having been forced upward, the liquid flowing out of the meter resists having its vertical motion decreased by pushing up on the tube. This action causes the tube to twist. When the tube is moving downward during the second half of its vibration cycle, it twists in the opposite direction.

Having been forced upward, the liquid flowing out of the meter resists having its vertical motion decreased by pushing up on the tube. This action causes the tube to twist. When the tube is moving downward during the second half of its vibration cycle, it twists in the opposite direction. The ammount of twist is directly proportional to the mass flow rate of the liquid flowing through the tube. Magnetic sensors located on each side of the flow tube measure the tube velocities, which change as the tube twists. The sensors feed this information to the electronics unit, where it is processed and converted to a voltage proportional to mass flow rate. The meter has a wide range of applications from adhesives and coatings to liquid nitrogen.

This meter has extremely high accuracy but can also cause a high pressure drop.(Back to Meter Types Table)

Thermal-type mass flowmeters have traditionally been used for gas measurements, but designs for liquid flow measurements are available. These mass meters also operate independent of density, pressure, and viscosity. Thermal meters use a heated sensing element isolated from the fluid flow path. The flow stream conducts heat from the sensing element. The conducted heat is directly proportional to the mass flow rate. The sensor never comes into direct contact with the liquid, Fig. 12. Through pre-existing built-in calibrations, the temperature differential is translated to mass flow. The accuracy of the thermal mass flow device is dependent on the reliability of the calibrations of the actual process gas or liquid and variations in the temperature, pressure, flow rate, heat capacity and viscosity of the fluid. The electronics package includes the flow analyzer, temperature compensator, and a signal conditioner that provides a linear output directly proportional to mass flow. (Back to Meter Types Table)

Open Channel Meters

The "open channel" refers to any conduit in which liquid flows with a free surface. Included are tunnels, nonpressurized sewers, partially filled pipes, canals, streams, and rivers. Of the many techniques available for monitoring open-channel flows, depth-related methods are the most common. These techniques presume that the instantaneous flow rate may be determined from a measurement of the water depth, or head. Weirs and flumes are the oldest and most widely used primary devices for measuring open-channel flows.

Weirs operate on the principle that an obstruction in a channel will cause water to back up, creating a high level (head) behind the barrier. The head is a function of flow velocity, and, therefore, the flow rate through the device. Weirs consist of vertical plates with sharp crests. The top of the plate can be straight or notched. Weirs are classified in accordance with the shape of the notch. The basic types are V-notch, rectangular, and trapezoidal.(Back to Meter Types Table)

Flumes are generally used when head loss must be kept to a minimum, or if the flowing liquid contains large amounts of suspended solids. Flumes are to open channels what venturi tubes are to closed pipes. Popular flumes are the Parshall and Palmer-Bowlus designs.

The Parshall flume consists of a converging upstream section, a throat, and a diverging downstream section. Flume walls are vertical and the floor of the throat is inclined downward. Head loss through Parshall flumes is lower than for other types of open-channel flow measuring devices. High flow velocities help make the flume self-cleaning. Flow can be measured accurately under a wide range of conditions.

Palmer-Bowlus flumes have a trapezoidal throat of uniform cross section and a length about equal to the diameter of the pipe in which it is installed. It is comparable to a Parshall flume in accuracy and in ability to pass debris without cleaning. A principal advantage is the comparative ease with which it can be installed in existing circular conduits, because a rectangular approach section is not required.

Discharge through weirs and flumes is a function of level, so level measurement techniques must be used with the equipment to determine flow rates. Staff gages and float-operated units are the simplest devices used for this purpose. Various electronic sensing, totalizing, and recording systems are also available.

A more recent development consists of using ultrasonic pulses to measure liquid levels. Measurements are made by sending sound pulses from a sensor to the surface of the liquid, and timing the echo return. Linearizing circuitry converts the height of the liquid into flow rate. A strip chart recorder logs the flow rate, and a digital totalizer registers the total gallons. Another recently introduced microprocessor-based system uses either ultrasonic or float sensors. A key-pad with an interactive liquid crystal display simplifies programming, control, and calibration tasks.(Back to Meter Types Table)

Want more information on Piston Type Circulating Real Gas Flow Standard Device? Feel free to contact us.