Uninterrupted Power Supply Unit Industrial UPS 6kVA ...

09 Sep.,2024

 

Uninterrupted Power Supply Unit Industrial UPS 6kVA ...



Uninterrupted power supply unit low frequency industrial ups 6kva 10kva 40kva 60kva 80kva 100KVA 120kva

Please visit our website for more information on this topic.



HIGHLIGHTS
&#; Efficiency Control System (ECS)
&#; Robust and reliable
&#; Galvanic isolation
&#; High overload capacity
&#; Extensive parallel configurations



Total protection
DPL series UPS provides maximum protection and power quality for mission critical loads, including data centres, industrial processes, telecommunications, security and electro-medical systems. DPL series UPS is an on-line double conversion UPS with a transformer isolated inverter. DPL range includes three-phase input and single-phase output versions from 10 to 100 kVA, and three-phase input and output versions from 10 to 200 kVA. All versions are provided with a 6-pulse thyristor-based rectifier, with or without optional harmonic filters. A 12-pulse thyristor-based rectifier is available on request for the 60 and 80 kVA versions with or without optional harmonic filters.

Easy source
DPL series makes supplying the UPS from generator sets and MT/BT transformers simpler and more efficient, reducing power loss in the system and coils, correcting the power factor and eliminating current harmonics created by the loads supplied by the UPS.
In addition to this, the progressive rectifier start-up (power walk-in) and the option to reduce battery charging currents, allow for a reduction in the input current uptake. This means less demand on the source, which is particularly useful when the source is a generator set.

Flexibility
DPL series is suitable for a wide range of applications including IT and the most demanding industrial environments. The UPS is suitable for power capacitive loads such as blade servers, from 0.9 leading to 0.8 lagging. With a broad range of accessories and options, complex configurations and system architectures can be achieved to guarantee maximum power availability and the option to add new UPS without interruption to existing installation.

Battery care system: maximumbattery care
Normally the batteries are kept charged by the rectifier; when mains power fails, the UPS uses this energy source to power the consumers. Proper battery care is therefore critical to ensuring correct UPS operation under emergency conditions. DPL series of UPS battery care system consists of a series of functions designed to optimise battery management and achieve the best performance and operating life possible. DPL series is also compatible with different battery technologies: vented open lead acid, VRLA AGM, Gel, NiCd and Lithium.

Advanced communications
&#; Compatible with UPS management system for remote monitoring.
&#; Advanced multi-platform communications for all operating systems and network environments.
&#; Double RS232 serial
&#; 2 slots for the installation of optional communications accessories such as network adapters, potential free contacts, etc.
&#; EPO: Emergency Power Off for switching off the UPS via the emergency button
&#; Input for the connection of the auxiliary contact of an external manual bypass
&#; Input for synchronisation from an external source
&#; Graphic display panel for remote connection


 


Specifications

Model

31 10K

31 15K

31 20K

Phase

Three phase in /Single phase out

Input

Rate capacity

10KVA/8KW

15KVA/12KW

20KVA/16KW

Rate voltage

400VAC

(

three phase with ground

)

Turn on voltage range 

190-520VAC

(

three phase

)

  &#;50% load

305-520VAC

(

three phase

)

  &#;100% load

Frequency range

46~54Hz or 56~64Hz

Output

Rate voltage

220/230/240VAC

Voltage regulation

±1%

Line mode frequency

46~54Hz or 56~64Hz

Bat mode frequency

50Hz or 60Hz

Voltage harmonic

&#;3%   R load

;

       &#;5%   RCD load

Crest ration

3:01

Line-Bat transfer

0ms

INV-Bypass transfer

0ms

Over load

105%±5%<load&#;125%±5%

:

1min

;

125%±5%< load &#;150%±5%

:

30s

;

For more information, please visit hbcy.

load>150%±5%

:

300ms;   ( transfer to bypass and alarm)

Efficiency

Line mode

> 91%

Bat mode

> 91%

Battery

Number

16 or 20

Charger voltage

218.4VDC/273VDC

Charge current (stand)

1A/2A/4A adjustable

,

default 1A

Charge current(long)

1A/2A/4A adjustable

,

default 4A

Size

(

length*width*height

)

and weight

Stand UPS(mm)

442*190*688

575*190*688

Weight(kg)

66/76

68/78

80(only 20 BAT)

LongtimeUPS(mm)

442*190*318

575*190*318

Weight(kg)

15

16

19

Environment

Work temperature

0

ºC~

40

ºC

Work humidity

20%

~

95

%

Audible noise

&#;60dB

Communication

RS-232/USB/SNMP card

If you are looking for more details, kindly visit 6-40kVA Multi-Scenario UPS System.