You may already come across the issue of faceted curtain panels and mullions in the curved curtain wall. Revit doesnt allow the curved curtain wall by default unless the curtain panel is actually created as the curved panel, but the mullion cannot be curved. It is quite difficult to create the curved curtain panel with mullions as a parametric family and to make it work as expected.
Of course, you can use the system curtain panel and modify it like the in-place model, but it is difficult to update the design changes. It should be able to follow the curtain wall line to reduce the amount of work to update the changes.
Select the Curtain Panel and click the Edit In-Place button in Modify tap
Dont Edit Extrusion as it has the vertical reference plane. Delete the extrusion and re-create it on the horizontal reference plan (Level). Draw the outline and adjust the height
When finished, click the Finish Model Button However, there is no way to make the curved mullion, so make sure to include the mullion in the curtain panel.
Curtain panel can be a wall
The wall element can be inserted to the curtain wall as curtain panel and the wall can be curved!
Zhuzao Product Page
Before replacing the panel, you need to remove the curtain grid in the section since it cannot be used.
Select the curtain panel and unpin it if it is pinned
Search the wall type and select it
Relocate the wall to align to other panels
How about the mullions?
The mullion cannot be curved so there should be something to use with the wall. As the wall element is used for the curtain panel, it makes sense to use the wall sweep to present the mullion. Again, it is not automatically updated to match the curtain grid, but it is still a good choice to show the graphic you want.
Activate any 3d view
Go to Architecture tap and click the drop-down button in Wall, select Wall Sweep
Select the wall sweep type, which has the same profile as the mullion
Place the sweep on the wall
Adjust the wall sweep location to match the curtain grid
Change the Offset from Wall value to align the sweep
To Sum up
It is not the best way to resolve the issue, but modelling should be flexible in the design phase if the tool has the limitation. It should be replaced by the proper curtain panel for the construction stage to quantify the panel numbers although it is a time-consuming task.
This page has been translated for your convenience with an automatic translation service. This is not an official translation and may contain errors and inaccurate translations. Autodesk does not warrant, either expressly or implied, the accuracy, reliability or completeness of the information translated by the machine translation service and will not be liable for damages or losses caused by the trust placed in the translation service.